VTM10X(n)
描述
VMECA Minimultiple Pumps are stacked with mini pumps. Each pump creates vacuum as an individual pump. The advantages of this unit is that it can be operated using just two control valve while retaining individual vacuum lines separate to one another, therefore if any leakage or surface deformation occurs and one pad loses it vacuum, it does not effect the vacuum level in the other pads. Pumps can be stacked up from 2-12 units depending upon requirements.
Build an Order #
1. Basic Model
Code | Description |
VTM10 | Minimultiple, VTM10 |
2. Number of Stacks
Code | Description |
2 | Minimultiple, VTM10, 2-stacked pump |
4 | Minimultiple, VTM10, 4-stacked pump |
6 | Minimultiple, VTM10, 6-stacked pump |
8 | Minimultiple, VTM10, 8-stacked pump |
10 | Minimultiple, VTM10, 10-stacked pump |
12 | Minimultiple, VTM10, 12-stacked pump |
3. Air Control Valve
Code | Description |
Blank | No air control valve |
A1 | Air control valve, AC 110V |
A2 | Air control valve, AC 220V |
A3 | Air control valve, DC 24V |
4. Valve Terminal
Code | Description |
Blank | No air control valve ☛ “Option 2”, Air control valve |
DN | Solenoid terminal, DIN type, No lead wire |
DL | Solenoid terminal, DIN type, No lead wire, Lamp |
CL | Solenoid terminal, Connector type, 30 cm lead wire |
☛ “The valve terminal ” option is only available when you chose air control valve. | |
☛ “CL” option is only available with DC24V. | |
2B | Solenoid terminal, DIN, 2-in-1 BUS cable |
5. Vacuum Port
Code | Description |
2 | Push-in fitting, 2 mm inner diameter |
4 | Push-in fitting, 4 mm inner diameter |
6. Sealing Material
Code | Description |
Blank | NBR sealing material |
V | Viton sealing material |
E | EPDM sealing material |
Specifications
1. General Specifications
Max Vacuum Level | -85 kPa |
Open Vacuum Flow | 35 Nl/min |
Feed Pressure | 5.5 bar (Max 7 bar) |
Air Consumption | 42 Nl/min |
Temperature | -20 ~ 80 ℃ |
Weight – 2-stacked pump | 67 g (Increased 13 g per additional stack) |
2. Vacuum Flow
Max Vacuum | Feed Pressure | Vacuum Flow (Nl/min) at different vacuum level (-kPa) | |||||||||
-kPa | bar | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
85 | 5.5 | 35 | 29 | 25 | 23 | 19 | 16 | 12 | 4.8 | 1.32 | – |
3. Evacuation Time
Feed Pressure | Air Consumption | Evacuation time in sec per liter to reach different vacuum level (-kPa) | ||||||||
bar | Nl/min | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
5.5 | 42 | 0.109 | 0.278 | 0.50 | 0.788 | 1.178 | 1.72 | 2.635 | 5.158 | – |
Dimensions
Dimensions
VTM10X(2~3): |
VTM10X(4~12): |
Order Numbers
Vacuum Pumps & Spare Parts
Part Number | Description |
MS18-3-1 | 2/2-way sol valve, G1/8″ inlet, DC 24V, DIN type |
MS18-3-2 | 2/2-way sol valve, G1/8″ inlet, DC 24V, DIN type, Lamp |
MS18-3-3 | 2/2-way sol valve, G1/8″ inlet, DC 24V, Conn. type, 30 cm lead wire & Lamp |
MS18-2-1 | 2/2-way sol valve, G1/8″ inlet, AC 220V, DIN type |
MS18-2-2 | 2/2-way sol valve, G1/8″ inlet, AC 220V, DIN type, Lamp |
MS18-1-1 | 2/2-way sol valve, G1/8″ inlet, AC 110V, DIN type |
MS18-1-2 | 2/2-way sol valve, G1/8″ inlet, AC 110V, DIN type, Lamp |
Seal Kit | Please contact VMECA. |