Description

The VQ series has been equipped with a unique capability called the “Blow-Off”.  The way this blow off system works is that it holds compressed air inside a chamber built in the vacuum speeder. This chamber holds the air until the compressed air is cut off, allowing the air within the chamber to come out and release the product quickly.

Build an Order #


1. Basic Model

Symbol Description
VQ203S VQ pump, 3-stage cartridge, Twofold silencer

2. Vacuum Port

Symbol Description
38F G3/8 female, Vacuum port

3. Vacuum Switch

Symbol Description
Blank No vacuum switch
S2 Digital vacuum switch, No analog supply, M8-4-pins, NPN
S2P Digital vacuum switch, No analog supply, M8-4-pins, PNP
SG2 Digital vacuum switch, No analog supply, Grommet, NPN
SG2P Digital vacuum switch, No analog supply, Grommet, PNP
SG3 Digital vacuum switch, Analog supply, Grommet, NPN
SG3P Digital vacuum switch, Analog supply, Grommet, PNP
S LED vacuum switch, No analog supply, M8-3-pins, NPN
SP LED vacuum switch, No analog supply, M8-3-pins, PNP
SG LED vacuum switch, No analog supply, Grommet, NPN
SGP LED vacuum switch, No analog supply, Grommet, PNP

4. Sealing Material

Symbol Description
Blank NBR sealing material
V Viton sealing material
E EPDM sealing material

Specifications

1. General Specifications

Max Vacuum Level -90 kPa
Open Vacuum Flow 85 Nl/min
Feed Pressure 1.7 ~ 4 bar (Max 7 bar)
Air Consumption 40 Nl/min @ 4 bar
Temperature -20 ~ 80 ℃
Weight – Basic pump 160 g

2. Vacuum  Flow

Max Vacuum Feed Pressure Vacuum Flow (Nl/min) at different vacuum level (-kPa)
-kPa bar 0 10 20 30 40 50 60 70 80 90
90 3.14 84 37.5 26 16 15.2 12.3 10 7.2 4
89 4 84.5 40 33.2 22.6 15.8 12 9.2 7.3 2.9
65 2.2 68 31 16.5 15.5 13.8 9 3.5
49 1.7 55 23.2 15.5 12.6 6.1

3. Evacuation Time

Feed Pressure Air Consumption Evacuation time in sec per liter to reach different vacuum level (-kPa)
bar Nl/min 10 20 30 40 50 60 70 80 90
3.14 34 0.06 0.28 0.51 1.01 1.18 1.29 1.73 3
4 40 0.08 0.24 0.50 0.71 0.85 1.18 1.41 3.05
2.2 26 0.08 0.39 0.59 0.85 0.96 1.10
1.7 22 0.13 0.40 0.79 1.57  –

Dimensions

VQ203S:
Unit: mm

No Description
1 Compressed-Air Supply Port, G1/8″
2 Vacuum Port, G3/8″
3 Exhaust Port
4 Vacuum Switch, VP10 series
5 Two-Fold Silencer, VC203S

Order Numbers

Basic Vacuum Pump & Spare Parts